Drug of Abuse Rapid Cassette Test-COC Urine Test Cassette-colloidal Gold

Drug of Abuse Rapid Cassette Test-COC Urine Test Cassette-colloidal Gold
Chat Now
Product Details

Drug Of Abuse Rapid Cassette Test Cocaine (COC) Urine Test Cassette 

(Colloidal Gold)


1.Product Description

(1)Cocaine is a potent central nervous system (CNS) stimulant and a local anesthetic.Physical symptoms following short-term use include extreme energy and restlessness; following sustained use, symptoms may include tremors, over-sensitivity and spasms. In large doses, cocaine use may cause fever, unresponsiveness, difficulty in breathing and unconsciousness.

(2)Cocaine is often self-administered by nasal inhalation, intravenous injection and free-base smoking.It is excreted in the urine in a short time primarily as Benzoylecgonine,Benzoylecgonine,a major metabolite of cocaine, has a longer biological half-life (5-8 hours) than cocaine (0.5-1.5 hours), and can generally be detected for 24-48 hours after cocaine exposure.

(3)The COC One Step Test Device yields a positive result when the cocaine metabolite in urine exceeds 150ng/mL. At present, the recommended screening cutoff for cocaine positive specimens as set by the Substance Abuse and Mental Health Services Administration (SAMHSA) is 300 ng/mL.

Drug Control.jpg


2.Specification

COC One Step Cocaine Test Strip

DCO-101

Strip

Urine

300ng/mL

Strip: 100pcs/box
Cassette: 10 or 40pcs/box Customized

COC One Step Cocaine Test Device

DCO-102

Cassette

Urine

300ng/mL

Strip: 100pcs/box
Cassette: 10 or 40pcs/box Customized

COC 150 One Step Cocaine Test Device

DCO-U102

Cassette

Urine

150ng/mL

Strip: 100pcs/box
Cassette: 10 or 40pcs/box Customized

The COC Drug Urine Test Cassette 1.JPG

                                                    cocaine

可卡因


3.Interpretation of Results

(1)NEGATIVE:* Two lines appear. One red line should be in the control region (C), and another apparent red or pink line should be in the test region (T). This negative result indicates that the Benzoylecgonine concentration is below the detectable level (150ng/mL).

(2)* NOTE:The shade of red in the test region (T) may vary, but it should be considered negative whenever there is even a faint pink line.

(3)POSITIVE: One red line appears in the control region (C). No line appears in the test region. This positive result indicates that the Benzoylecgonine concentration is above the detectable level (150ng/mL).

(4)INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test device. If the problem persists, discontinue using the lot immediately and contact your local distributor.

PEAL921A7Z7C)B_GPTY)GEF.png

COC.jpg


4.Materials Provided

(1)Test devices 

(2)Disposable specimen droppers

(3)Package insert         




Hangzhou Laihe Biotech Co., Ltd

Contact: Helen

Tel: +86-571-86658003

Fax: +86-571-86658000

E-mail: office@lyher.com

Zip:310052



Feedback